Free Standing Lifting Stations (Sanicubic)

Sanicubic 2 SC

Ambient visual of a Sanicubic 2 SC3.0 T, three-phase, lifting station for wastewater/sewage to be installed in a warehouse.

Sanicubic 2 SC

Wastewater lifting station for commercial aplications. The SANICUBIC 2 SC is a two-motor wastewater lifting pump equipped with a single-channel impeller. Designed for commercial applications, it can lift wastewater from public buildings or shopping centres. This lifting station is available in 4 versions. It comes with a pneumatic remote-control box, which includes an audible and visual alarm.
* Single-channel cutting blade
* Available in three phases
* 4 versions: from 125 to 175 m3/h discharge
* Tank volume: 1000 litres
* IP68 rating
Find out more

Product details

- The Sanicubic 2 SC is a wastewater lifting pump that comes with 2 IP68 certified motors, each with a single channel high performance cutting blade. The Sanicubic 2 SC wastewater lift pump is currently available in 4 different versions for 4 high volume lifting performances. This Sanicubic 2 SC pump has a DN 150 inlet for lifting large volumes of wastewater from commercial environments.

- The SFA wastewater lift pump is delivered with a remote-control box as well as an audible and visual alarm for added safety and peace of mind. This SFA wastewater lift pump is designed for easy servicing and regular maintenance.

- The Sanicubic 2 SC comes with a standard 2-year warranty. With 60 years of expertise and innovation, Sanicubic 2 SC is designed, made, and tested in France.

Benefits of installing the Sanicubic 2 SC pump:
This pump comes equipped with a single-channel impeller.
It is currently available in three phases.
It has 4 versions ranging from 125 to 175 m3/h of discharge.
Can handle water temperatures of up to 55°C (5min max).
This lifting station also comes with an audible and visual alarm for added safety.

Applications of the Sanicubic 2 SC Pump:
- Restaurants, foodservice establishments, office complexes, hotels, resorts, shopping centres, malls, factories, warehouses, schools, hospitals, sports centres, and government buildings.

Why choose Sanicubic 2 SC pump?:
High Capacity: The Sanicubic 2 SC is designed to handle a higher volume of waste and water, making it suitable for larger residential properties, commercial buildings, and multi-unit installations.
Dual Motors: Equipped with two powerful motors, the Sanicubic 2 SC provides redundancy and ensures continuous operation. If one motor fails, the second can continue to operate, enhancing reliability.
Integrated Non-Return Valves: The unit includes integrated non-return valves to prevent backflow, ensuring that wastewater moves in the right direction and preventing contamination.
Adaptability to Different Waste Types: The pump is capable of handling various types of waste, including grey water and black water, making it a versatile solution for diverse applications.
IP68 Rated: The Sanicubic 2 SC is IP68 rated, indicating its high level of protection against dust and water, making it suitable for use in challenging environments.

Frequently asked questions (FAQs):
Q1. What waste can the Sanicubic 2 SC pump handle?
A: The Sanicubic 2 SC pump is designed to handle all types of wastewater, including black water from toilets and grey water from sinks, showers, and washing machines.

Q2. Where can the Sanicubic 2 SC pump be installed?
A: It can be installed in basements, utility rooms, garages, and other locations where traditional gravity drainage is not feasible. The station can also be installed below ground level in a pit.

Q3. What is the maximum discharge height for the Sanicubic 2 SC pump?
A: The Sancubic 2 SC pump has 4 different versions, which can pump wastewater from 10 m up to 22 m vertically. For more information, click here to connect with our sales expert.
Technical specification

Sanicubic 2 SC

  • Version
  • Version
  • Version
  • Version
  • Sanicubic 2 SC3.0 T
  • Version
  • Sanicubic 2 SC4.0 T
  • Version
  • Sanicubic 2 SC5.5 T
  • Version
  • Sanicubic 2 SC7.5 T

Materials

  • Shaft
  • Tank
  • Pump housing
  • Seal
  • Motor housing
  • Impeller
  • Shaft
  • Shaft
  • Tank
  • Tank
  • Pump housing
  • Pump housing
  • Seal
  • Seal
  • Motor housing
  • Motor housing
  • Impeller
  • Impeller
  • Shaft
  • Stainless steel
  • Tank
  • PE HD
  • Pump housing
  • EN-GJL-200
  • Seal
  • carbon/ceramic
  • Motor housing
  • EN-GJL-200
  • Impeller
  • EN-GJL-200
  • Shaft
  • Stainless steel
  • Tank
  • PE HD
  • Pump housing
  • EN-GJL-200
  • Seal
  • carbon/ceramic
  • Motor housing
  • EN-GJL-200
  • Impeller
  • EN-GJL-200
  • Shaft
  • Stainless steel
  • Tank
  • PE HD
  • Pump housing
  • EN-GJL-200
  • Seal
  • carbon/ceramic
  • Motor housing
  • EN-GJL-200
  • Impeller
  • EN-GJL-200
  • Shaft
  • Stainless steel
  • Tank
  • PE HD
  • Pump housing
  • EN-GJL-200
  • Seal
  • carbon/ceramic
  • Motor housing
  • EN-GJL-200
  • Impeller
  • EN-GJL-200

Electrical features

  • Number of motor(s)
  • Socket included
  • Voltage (V)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • IP Rating
  • Electrical class
  • Motor insulation class
  • Mode of operation
  • Current
  • Length of cable-control box (m)
  • Number of pumps
  • Type of control box
  • Number of motor(s)
  • Number of motor(s)
  • Socket included
  • Socket included
  • Voltage (V)
  • Voltage (V)
  • Frequency (Hz)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • Maximum current (A)
  • IP Rating
  • IP Rating
  • Electrical class
  • Electrical class
  • Motor insulation class
  • Motor insulation class
  • Mode of operation
  • Mode of operation
  • Current
  • Current
  • Length of cable-control box (m)
  • Length of cable-control box (m)
  • Number of pumps
  • Number of pumps
  • Type of control box
  • Type of control box
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 400
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 4000
  • Power output P2 (W)
  • 3000
  • Revolution per minute (RPM)
  • 1400
  • Maximum current (A)
  • 6.9
  • IP Rating
  • IP56
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Mode of operation
  • S3 25 %
  • Current
  • Three-phase
  • Length of cable-control box (m)
  • 3,5
  • Number of pumps
  • 2
  • Type of control box
  • ZPS 2 case
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 400
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 5500
  • Power output P2 (W)
  • 4000
  • Revolution per minute (RPM)
  • 1400
  • Maximum current (A)
  • 11.2
  • IP Rating
  • IP56
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Mode of operation
  • S3 25 %
  • Current
  • Three-phase
  • Length of cable-control box (m)
  • 3,5
  • Number of pumps
  • 2
  • Type of control box
  • ZPS 2 case
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 400
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 6300
  • Power output P2 (W)
  • 5500
  • Revolution per minute (RPM)
  • 1400
  • Maximum current (A)
  • 12.1
  • IP Rating
  • IP56
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Mode of operation
  • S3 25 %
  • Current
  • Three-phase
  • Length of cable-control box (m)
  • 3,5
  • Number of pumps
  • 2
  • Type of control box
  • ZPS 2 case
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 400
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 8700
  • Power output P2 (W)
  • 7500
  • Revolution per minute (RPM)
  • 1400
  • Maximum current (A)
  • 16.9
  • IP Rating
  • IP56
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Mode of operation
  • S3 25 %
  • Current
  • Three-phase
  • Length of cable-control box (m)
  • 3,5
  • Number of pumps
  • 2
  • Type of control box
  • PS2 System case

Hydraulic

  • Max. Head (m)
  • Max. flow rate (m³/h)
  • Number of inlets
  • Inlet diameter DN (mm)
  • Discharge diameter DN
  • Ventilation diameter DN
  • Total volume (L)
  • Useable volume (L)
  • Free passage (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Type of impeller
  • Type of activation
  • Max. Head (m)
  • Max. Head (m)
  • Max. flow rate (m³/h)
  • Max. flow rate (m³/h)
  • Number of inlets
  • Number of inlets
  • Inlet diameter DN (mm)
  • Inlet diameter DN (mm)
  • Discharge diameter DN
  • Discharge diameter DN
  • Ventilation diameter DN
  • Ventilation diameter DN
  • Total volume (L)
  • Total volume (L)
  • Useable volume (L)
  • Useable volume (L)
  • Free passage (mm)
  • Free passage (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Type of impeller
  • Type of impeller
  • Type of activation
  • Type of activation
  • Max. Head (m)
  • 10
  • Max. flow rate (m³/h)
  • 120
  • Number of inlets
  • 1
  • Inlet diameter DN (mm)
  • 150
  • Discharge diameter DN
  • 100
  • Ventilation diameter DN
  • 100
  • Total volume (L)
  • 1000
  • Useable volume (L)
  • 500
  • Free passage (mm)
  • 80
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 55°C
  • Type of impeller
  • single-channel
  • Type of activation
  • pneumatic
  • Max. Head (m)
  • 13
  • Max. flow rate (m³/h)
  • 140
  • Number of inlets
  • 1
  • Inlet diameter DN (mm)
  • 150
  • Discharge diameter DN
  • 100
  • Ventilation diameter DN
  • 100
  • Total volume (L)
  • 1000
  • Useable volume (L)
  • 500
  • Free passage (mm)
  • 80
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 55°C
  • Type of impeller
  • single-channel
  • Type of activation
  • pneumatic
  • Max. Head (m)
  • 18
  • Max. flow rate (m³/h)
  • 160
  • Number of inlets
  • 1
  • Inlet diameter DN (mm)
  • 150
  • Discharge diameter DN
  • 100
  • Ventilation diameter DN
  • 100
  • Total volume (L)
  • 1000
  • Useable volume (L)
  • 500
  • Free passage (mm)
  • 100
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 55°C
  • Type of impeller
  • single-channel
  • Type of activation
  • pneumatic
  • Max. Head (m)
  • 22
  • Max. flow rate (m³/h)
  • 165
  • Number of inlets
  • 1
  • Inlet diameter DN (mm)
  • 150
  • Discharge diameter DN
  • 100
  • Ventilation diameter DN
  • 100
  • Total volume (L)
  • 1000
  • Useable volume (L)
  • 500
  • Free passage (mm)
  • 100
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 55°C
  • Type of impeller
  • single-channel
  • Type of activation
  • pneumatic

Logistics

  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • 370
  • Gross weight (kg)
  • 385
  • Gross weight (kg)
  • 400
  • Gross weight (kg)
  • 425

General description

  • EAN code
  • EAN code
  • EAN code
  • EAN code
  • 3308815079073
  • EAN code
  • 3308815079080
  • EAN code
  • 3308815079097
  • EAN code
  • 3308815079103
Quality

Buy with confidence

  • Made in France

    Many products have received the Made in France label.

  • Performance and Reliability

    Technologies and materials that ensure efficiency and longevity.

  • Long-term Warranty

    2 years for all products.

  • Technical support

    We have certified installers and repair technicians.

  • Experts Since 1958

    Creator of the Sanibroyeur macerating toilet.